English (GB)
52
13.37 "Connection code"
This menu is only available in Grundfos GO.
You can set a connection code to avoid having to
press the connection button each time and to restrict
remote access to the product.
Setting the code in the product using Grundfos
GO
1. Connect Grundfos GO to the product.
2. In the product dashboard, select "Settings".
3. Choose "Connection code".
4. Enter the wanted code and press [OK].
The code must be a character string (ASCII).
You can always change the code. The old code is
not needed.
Setting the code in Grundfos GO
You can define a default connection code in
Grundfos GO so that it automatically attempts to
connect to the selected product via this code.
When you select a product with the same connection
code in Grundfos GO, Grundfos GO automatically
connects to the product and you do not have to press
the connection button on the module.
Define the default code in Grundfos GO in this way:
1. In the main menu, under "General", select
"Settings".
2. Choose "Remote".
3. Enter the connection code in the field "Preset
connection code". The field now says
"Connection code set".
You can always change the default connection code
by pressing [Delete] and entering a new one.
If Grundfos GO fails to connect and ask you to press
the connection button on the product, it means that
the product has no connection code or has a
different connection code. In this case, you can only
establish connection via the connection button.
13.38 Run start-up guide
This menu is only available in the advanced control
panel.
The startup guide automatically starts when you start
the pump for the first time.
You can always run the startup guide later via this
menu.
The startup guide guides you through the general
settings of the pump.
• Language. See section 13.27 Language.
• Select date format.*
See section 13.28 "Date and time" (Set date and
time).
• Set date.*
See section 13.28 "Date and time" (Set date and
time).
• Select time format.*
See section 13.28 "Date and time" (Set date and
time).
• Set time.*
See section 13.28 "Date and time" (Set date and
time).
• Setting of pump "
– Go to Home
– Run with Constant curve/Run with Constant
pressure.
See section 13.5 "Control mode".
– Go to "Assisted pump setup".
See section 13.42 Assisted pump setup.
– Return to factory settings.
* Applies only for pumps fitted with advanced
functional module, FM 300. For further
information, see section 19. Identification of
functional module.
13.39 Alarm log
This menu contains a list of logged alarms from the
product. The log shows the name of the alarm, when
the alarm occurred and when it was reset.
Pump variant "Connection code"
CME ●
CRE, CRIE, CRNE,
SPKE, MTRE
●
After setting a connection code, switch off
the product until the light in Grundfos Eye
turns off before you can use the new
connection code.
Pump variant Run start-up guide
CME ●
CRE, CRIE, CRNE,
SPKE, MTRE
●