Example
:OUTPut2:OVP:STATe?
Returns the status of the OVP function on CH2.
Command
:OUTPut[1|2|3]:OVP:TRIGer?
Function
Query whether the OVP protection function has
been triggered.
Return
0/OFF: The channel OVP protection is not
triggered.
1/ON: The channel OVP protection has been
triggered.
Example
:OUTPut2:OVP:TRIGer?
Return whether the OVP protection function of
channel 2 has been triggered.
Command
:OUTPut[1|2]:OVP <value>
Function
Sets the OVP level.
Description
<value>
Refer to the specification sheet on
page 200 for value.
Example
:OUTPut2:OVP 10.5
Sets the OVP voltage to 10.5V for CH2.
Note
About CH3, The OVP value can not be set.
Command
:OUTPut[1|2|3]:OVP?
Function
Queries the OVP voltage level.
Example
:OUTPut2:OVP?
Queries the OVP voltage level on CH2.
Note
About CH3, OVP query value is 5.5V.