REMOTE CONTROL
143
Example
:OUTPut:PARallel ON
Sets CH1/CH2 as tracking parallel mode.
Command
TRACK<NR1>
Function
Selects the operation mode: independent, tracking
series, or tracking parallel. Series-parallel mode is
not supported under LOAD.
NR1 0: Independent, 1: Series, 2: Parallel
Example
TRACK0
Selects the independent mode.
Command
:LOAD[1|2]:CV {ON|OFF}[,FAST]
Function
Sets CH1/CH2 as Load CV mode. Automatically
switch to power mode after closing LOAD mode.
Description
[FAST]: In order to protect the function switching
device relay, it is necessary to wait until the
voltage and current drop to zero under normal
conditions. When FAST is enabled, this factor will
not be considered, but it is easy to damage the
relay, so it is recommended to use it with
caution.
Example
:LOAD2:CV ON
Sets CH2 as Load CV mode.
Command
:LOAD[1|2]:CC {ON|OFF}[,FAST]
Function
Sets CH1/CH2 as Load CC mode.