Page #144 background image
GPP-3060/6030 User Manual
144
Description
[FAST]: In order to protect the function switching
device relay, it is necessary to wait until the
voltage and current drop to zero under normal
conditions. When FAST is enabled, this factor will
not be considered, but it is easy to damage the
relay, so it is recommended to use it with
caution.
Example
:LOAD2:CC ON
Sets CH2 as Load CC mode.
Command
:LOAD[1|2]:CR {ON|OFF}
Function
Sets CH1/CH2 as Load CR mode.
Example
:LOAD2:CR ON
Sets CH2 as Load CR mode.
Command
:MODE[1|2]?
Function
Queries CH1 or CH2 work mode.
6 modes below:
SERies, PARallel, INDEpendent,
CV Load, CC Load, CR Load.
Example
:MODE1?
Queries CH1 work mode.
Command
:LOAD[1|2]: RESistor <NRf>
Function
Sets the Load CR level.
Description
<NRf>
1-1000
Example
:LOAD2:RESistor 100
Sets the Load CR level to 100Ω for CH2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPP-3060 and is the answer not in the manual?

GW Instek GPP-3060 Specifications

General IconGeneral
BrandGW Instek
ModelGPP-3060
CategoryPower Supply
LanguageEnglish

Related product manuals