80
Item S3100V3-10TP-PWR-SI S3100V3-20TP-PWR-SI S3100V3-28TP-PWR-SI
Chassis
leakage
current
compliance
UL60950-1/EN60950-1/IEC60950-1/GB4943
Melting
current of
power
module fuse
6.3 A/250 V 6.3 A/250 V 15 A/250 V
Cooling
system
Natural cooling without fan
trays
Using fixed fan trays to
intake cool air from the
chassis left side and
exhaust hot air from the
chassis right side
Using fixed fan trays to intake
cool air from the chassis left
side and port side and
exhaust hot air from the
chassis right side
Operating
temperature
5°C to +45°C (23°F to 113°F)
Operating
humidity
5% RH to 95% RH, noncondensing
Fire
resistance
compliance
UL60950-1/EN60950-1/IEC60950-1/GB4943