EasyManua.ls Logo

H3C S5130S-EI series - Symptom; Solution; Removable Power Supply Failure

H3C S5130S-EI series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-41
Table5-1 Power failure indication of the system status and RPS status LEDs
Power input type LED status Description
AC input The system status LED is off. AC power input failure
DC input
The system status LED or RPS status
LED is off.
DC power input failure
Concurrent AC and DC
inputs
The system status LED is off. AC and DC power inputs failure
The system status LED is on. The RPS
status LED is steady yellow.
AC input failure
The system status LED is on. The RPS
status LED is off.
DC input failure
Symptom
The system status LED is off, or RPS status LED is yellow or off. The AC or DC input failure has
occurred.
Solution
To resolve the issue:
1. Verify that the AC or DC power cord is correctly connected to the switch.
2. Verify that the AC-input or DC-input power receptacle on the switch and the connected AC or
DC power outlet are in good condition.
3. Verify that the AC or DC power source is operating correctly.
4. Verify that the operating temperature of the switch is in the acceptable range, and the power
supply has good ventilation. Overtemperature can cause the power supply to stop working and
enter protection mode.
5. If the issue persists, contact H3C Support.
Removable power supply failure
The S5130S-28F-EI and S5130S-52F-EI switches use removable power supplies. You can
determine the power supply operating status by examining the power supply LEDs PWR1 and
PWR2 on the switch front panel. For descriptions about the PWR1 and PWR2 LEDs, see LEDs in
Hardware Information and Specifications.
Symptom
A power supply LED on the front panel of the switch is not steady green.
Solution
To resolve the issue:
1. Verify that the AC or DC power cord is correctly connected to the switch.
2. Verify that the power supply model is as required.
3. Verify that the power supply is installed correctly in the switch.
4. Verify that the switch is operating in the acceptable temperature range.