1-7
Table1-4 Technical specifications for non-PoE switch models (3)
Item S5130S-28TP-EI S5130S-52TP-EI
S5130S-28S-EI
S5130S-28S-EI-M
S5130S-52S-EI
S5130S-52S-EI-M
Dimensions
(H × W × D)
43.6 × 440 × 160
mm (1.72 × 17.32 ×
6.30 in)
43.6 × 440 × 260
mm (1.72 × 17.32 ×
10.24 in)
43.6 × 440 × 160
mm (1.72 × 17.32 ×
6.30 in)
43.6 × 440 × 230 mm
(1.72 × 17.32 × 9.06
in)
Weight ≤ 2 kg (4.41 lb) ≤ 3.5 kg (7.72 lb) ≤ 2.5 kg (5.51 lb) ≤ 3.5 kg (7.72 lb)
Console port
• 1 × serial
console port
• 1 × micro USB
console port
When both ports are
connected, only the
micro USB console
port is available.
• 1 × serial
console port
• 1 × micro USB
console port
When both ports are
connected, only the
micro USB console
port is available.
• 1 × serial
console port
• 1 × micro USB
console port
When both ports are
connected, only the
micro USB console
port is available.
• 1 × serial
console port
• 1 × micro USB
console port
When both ports are
connected, only the
micro USB console
port is available.
10/100/1000
BASE-T
autosensing
Ethernet
port
26 (The two
highest-numbered
10/100/1000BASE-
T autosensing
Ethernet ports form
combo interfaces
with their
corresponding SFP
ports, respectively.)
50 (The two
highest-numbered
10/100/1000BASE-
T autosensing
Ethernet ports form
combo interfaces
with their
corresponding SFP
ports, respectively.)
24 48
SFP port
4 (The two
lowest-numbered
SFP ports form
combo interfaces
with their
corresponding
10/100/1000BASE-
T autosensing
Ethernet ports,
respectively.)
4 (The two
lowest-numbered
SFP ports form
combo interfaces
with their
corresponding
10/100/1000BASE-
T autosensing
Ethernet ports,
respectively.)
N/A N/A
SFP+ port N/A N/A 4 4
Input voltage
• Rated voltage: 100 VAC to 240 VAC @ 50 or 60 Hz
• Max voltage: 90 VAC to 264 VAC @ 47 to 63 Hz
Minimum
power
consumption
10 W 20 W 10 W 19 W
Maximum
power
consumption
24 W 42 W 24 W 44 W
Chassis
leakage
current
compliance
UL 62368-1/EN 62368-1/IEC 62368-1/UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1
Melting
current of
power
supply fuse
2 A/250 V 3.15 A/250 V 2 A/250 V 3.15 A/250 V
Cooling
system
Natural cooling
without fan trays
Using fixed fan trays
to draw ambient air
• Models with
product code
Using fixed fan trays
to draw ambient air in