6 Correcting POWER CLAMP Faults
6.1 Error messages
Error
message
Error
code
Possible cause Solution / Correction
Wrong
diameter
1 Wrong selection of shrink fit
chuck at the control panel
Choose the correct setting
Use the automatic function
Coil is too hot 8 Temperature in the coil
is too high
Allow coil to cool down for approx. 10 minutes
Coil missing 2 No coil connected Connect a coil
Coil connector defective Send the coil with the unit back to the manufacturer
for repair (see above the section "Service and
maintenance")
Coil is defective • Replace coil
Temperature too
high in the
housing
4 Temperature too high in
the housing
Allow the device to cool down
Device defective Send the unit back to the manufacturer
for repair (see above the section "Service and
maintenance")
Mains voltage
too low
16 Mains voltage too low Mains voltage must lie between 380 V and
500 V
Mains voltage
too high
32 Mains voltage too high Mains voltage must lie between 380 V and
500 V
Mains problem 48 Mains voltage drops
excessively during the shrink
fit process
When using an extension cable:
Connect the device directly with the outlet or try
using a cable with a larger cross-section.
Connect the device to a higher voltage outlet
Run a separate feed directly from the mains distribu-
tor to the machine
One phase missing in the
power supply
Check the fuses at the customers power supply
Have an electrician check whether all three phases
are present and connected correctly
(socket and plug of the machine)
Device defective Send the unit back to the manufacturer for repair
(see above the section "Service and maintenance")
Power section
errors
64 1 phase in power supply
missing or device defective
Have an electrician check whether all three phases
are present and connected correctly (socket and
plug of the machine)
Send the unit back to the manufacturer for repair
(see above the section "Service and maintenance")
Correcting Faults