6 Correcting POWER CLAMP Faults
6.1 Error messages
Error
message
Error
code
Possible cause Solution / Correction
Wrong
diameter
1 Wrong selection of shrink fit
chuck at the control panel
• Choose the correct setting
• Use the automatic function
Coil is too hot 8 Temperature in the coil
is too high
• Allow coil to cool down for approx. 10 minutes
Coil missing 2 No coil connected • Connect a coil
Coil connector defective • Send the coil with the unit back to the manufacturer
for repair (see above the section "Service and
maintenance")
Coil is defective • Replace coil
Temperature too
high in the
housing
4 Temperature too high in
the housing
• Allow the device to cool down
Device defective • Send the unit back to the manufacturer
for repair (see above the section "Service and
maintenance")
Mains voltage
too low
16 Mains voltage too low • Mains voltage must lie between 380 V and
500 V
Mains voltage
too high
32 Mains voltage too high • Mains voltage must lie between 380 V and
500 V
Mains problem 48 Mains voltage drops
excessively during the shrink
fit process
• When using an extension cable:
Connect the device directly with the outlet or try
using a cable with a larger cross-section.
• Connect the device to a higher voltage outlet
• Run a separate feed directly from the mains distribu-
tor to the machine
One phase missing in the
power supply
• Check the fuses at the customer’s power supply
• Have an electrician check whether all three phases
are present and connected correctly
(socket and plug of the machine)
Device defective • Send the unit back to the manufacturer for repair
(see above the section "Service and maintenance")
Power section
errors
64 1 phase in power supply
missing or device defective
• Have an electrician check whether all three phases
are present and connected correctly (socket and
plug of the machine)
• Send the unit back to the manufacturer for repair
(see above the section "Service and maintenance")
Correcting Faults