Service and maintenance
7.2.3 SPEED COOLER
Check the water level
Check the water level in the SPEED-COOLER at regular
intervals. Top it up as required with a mixture of clean
tap water and radiator antifreeze (mixing ratio 3:1).
The cooling coil in the water tank must be completely
covered.
Changing the water
Change the water at least once a year (see also the
section ‚Starting up‘).
• Drain the water tank, using a wet vacuum cleaner if
necessary.
• Fill the tank with a fresh water/anti-freeze mixture.
• Bleed the tubes of air.
Caution: Avoid direct contact with anti-freeze. Sur-
plus anti-freeze or water/anti-freeze mixtures must
be disposed of properly. They must not be placed
in domestic rubbish or released into the drains.
7.2.4 Replacement of the basic unit POWER
CLAMP
Repairs to the electronics of the POWER CLAMP should
only be carried out by the manufacturer.
In most cases it is only necessary to send the basic unit
with the electronics to the manufacturer. To do this, all the
add-on parts of the basic unit must be removed as follows:
POWER CLAMP Clamp Basic
• Unplug all the electrical cables on the left-hand side
of the unit
• Remove the screws (69) of the baseplate.
The basic unit is now free and can be sent for repair or
replaced.
69