EasyManua.ls Logo

HAIMER Basic - Other Errors

HAIMER Basic
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
Operating Manual
POWER CLAMP
English
Quality Wins.
© 2021/09 Haimer POWER CLAMP
Correcting Faults
6.2 Other errors
Problem Possible cause Solution / Correction
After switching on,
nothing can be
seen on the display
or only black bars
appear
Mains voltage under 350 V Connect the device to a higher voltage outlet.
Use a voltage transformer
One phase missing in the
power supply
Check the fuses at the customers power supply
Have an electrician check whether all three phases are
present and connected correctly (socket and plug of the
machine)
Defective display Send the unit back to the manufacturer for repair
(see above the section "Service and maintenance")
The shrinking proc-
ess is aborted after
a short period of
time (approx. 0.5
sec)
Major drop in the supplied
voltage
When using an extension cable: Connect the device
directly with the outlet or try using a cable with a larger
cross-section.
Connect the device to a higher voltage outlet
Run a separate feed directly from the main distributor to
the shrink fit machine.
One phase missing in the
power supply
Check the fuses at the customers power supply
Have an electrician check whether all three phases are
present and connected correctly (socket and plug of the
machine)
Device defective Send the unit back to the manufacturer for repair
(see above the section "Service and maintenance")
Tool or extension
cannot be unshrunk
properly
General notes Do not use excessive force to remove the tool from the
chuck. The clamping hole and shank could be damaged
Do not temper the chuck
For adjustable coils and
clamping diameter 3 – 5 mm
Use insert ring
Shank diameter is too great Only use tools with a shank tolerance of h6
Tool shank is dirty or dam-
aged (ridges, scratches, dents)
Clean the tool shank before shrinking in
Use undamaged tools only
Correct any unevenness (truing)
Wrong parameter settings at
the device
Set the correct setting in the display
Chuck holder not cooled
down completely
Always cool the chuck holder completely before using it
again
Chuck overheated (glowing) Shrinking and unshrinking are no longer possible. Send
the chuck with the tool to the manufacturer, repair may
be possible
Mains voltage too low • Connect the device to a higher voltage outlet
Use a voltage transformer
Power supply unstable. Volt-
age display sinks to under
495 V during the shrinking
process.
When using an extension cable:
Connect the device directly with the outlet or try using a
cable with a larger cross-section.
Connect the device to a higher voltage outlet
Run a separate feed directly from the main distributor to
the shrink fit machine

Table of Contents