Operating Manual
59
POWER CLAMP
English
Quality Wins.
© 2021/09 Haimer POWER CLAMP
6.3.1 Water pump does not start
• Switch off the SPEED COOLER
• Move (rotate) the fan wheel (65) of the motor (64) by
using a screwdriver placed through the cover (63) and
the motor protective cover.
• Remove the screwdriver
• Switch the cooler on
• Check whether the pump motor runs
If it does not start: there is an electrical defect
6.3.2 Setting the cooling temperature
The temperature of the cooling water is set at the factory
to approx. 18 °C. If the relative humidity is high or the
weather conditions are unfavourable the humidity in the
air can condense out on the cooling bodies. The cooling
body "sweats". In this case the temperature must be in-
creased somewhat.
Caution: This work should only be done by a skilled
electrician.
• Disconnect the mains cable
• Remove the cover (63)
• Remove the cover from the switchbox (66)
• Turn the temperature regulator by approx. 15° clockwise.
The cooling temperature is reduced if the temperature
regulator is turned counter-clockwise.
• Close the switchbox (66).
• Replace the cover (63)
Repeat the process if the cooling bodies still "sweat".
Correcting Faults