Operating Manual
65
POWER CLAMP
English
Quality Wins.
© 2021/09 Haimer POWER CLAMP
POWER CLAMP Profi Plus NG shrink fit machine:
Suitable for tools:
Coil NG ................................................................................ HM, Ø 3 - 32 mm, h6
HSS + extensions, 3 - 32 mm, h6
Large coil ..............................................................................HM, Ø 32 - 50 mm, h6
HSS + extensions, 32 - 50 mm, h6
Mains connection (the details given on the rating plate shall apply):
Nominal voltage ..................................................................3 x 400 - 480 V ˜
Min. actual operating voltage ........................................... 3 x 360 V ˜
Max. actual operating voltage .......................................... 3 x 500 V ˜
Frequency ............................................................................. 50 - 60 Hz
Power consumption ............................................................ 20 kVA
Fuse for mains supply .........................................................3 x 32 A
Unclamping and clamping time ......................................... approx. 5 seconds
Cooling air for the coil, if required ....................................approx. 2 bar and unoiled.
Dimensions (W x D x H) ..................................................... approx. 870 x 600 x 1,000 mm
Weight .................................................................................. approx. 45 kg
SPEED-COOLER high performance cooling unit:
Mains connection (the details given on the rating plate shall apply):
Nominal voltage ..................................................................230 V ˜
Frequency ............................................................................. 50 - 60 Hz
Power consumption ............................................................. 1 kVA
Fuse for mains supply .......................................................... 16 A
Water circuit:
Mixture of tap water and anticorrosive
Mixing ratio ..........................................................................3 : 1
Amount .................................................................................approx. 5 l
Cooling time .........................................................................20 to 150 seconds
Dimensions ........................................................................... approx. 565 x 440 x 335 mm
Weight .................................................................................. approx. 45 kg
Total dimensions incl. trolley ............................................... 600 x 1000 x 1530 mm
Overall weight incl. trolley ..................................................approx. 100 kg
Permitted environmental temperatures:
Storage and Transit .............................................................-25° to +70° C
Operation .............................................................................+5° to +40° C