HY8200 User’s Manual
48
[SOURce]:DYNamic:SLEW:FALL?
// Query the falling rate of the current in dynamic mode
7.6.29 [SOURce]:DYNamic:MODE
[SOURce]:DYNamic:MODE Set the operation mode for the dynamic mode
[SOURce]:DYNamic:MODE <mode>
CONTinuous | PULSe | TOGGle
DYN:MODE PULS
// Set the operation mode to pulse mode in dynamic mode
[SOURce]:DYNamic:MODE?
// Query the operation mode of the dynamic mode
7.6.30 [SOURce]:DYNamic:REPeat
[SOURce]:DYNamic:REPeat Se the repeat times for the dynamic mode
0
~
99999 | MINimum | MAXimum | LOOP
DYNamic:REPEAT 10
// Set the repeat times to 10 for the dynamic mode
[SOURce]:DYNamic:REPeat?
// Query the repeat times of the dynamic mode
7.6.31 [SOURce]:BATtery:MODE
[SOURce]:BATtery:MODE Set the operation mode in battery mode
[SOURce]:BATtery:MODE <mode>
CURRent | RESistance | POWer
BATery:MODE CURRent
// Set the operation mode to CC mode in battery mode
[SOURce]:BATtery:MODE?
// Query the operation mode in battery mode
7.6.32 [SOURce]:BATtery:CURRent
[SOURce]:BATtery:CURRent Set the load size of CC mode in battery mode
0.01~20 | MINimum| MAXimum