5.1
5 - Menu 1 Daily settings
Menu 1.1 Volume rate
How to change the volume rate
The volume rate can be changed by:
1. Setting the desired rate in the Controller.
2. Manually raising or lowering the pressure via the SetBox (HC 6400)
3. Pressing ¿ or ª to apply over or under in a preset percentage,
e.g. 10% (the % icon in the display indicates when this is active).
To read the volume rate: gal/acre
Shortcut ¥
Press ¥ and hold until menu [1.1 VOLUME RATE] is shown.
To change volume rate:
Move cursor with ¶ or § to the value to be changed.
Use ¿ or ª to change the value. Alternatively clear value by pressing | and key in value on the numeric keys.
Press # to confirm.
Manual dosage
To dose in manual mode, use the pressure buttons on the SetBox HC 6400. The manual mode is indicated by the ¬ symbol
at the top of the display.
To go from manual to preset volume rate, press AUTO.
μ
ATTENTION! Under 0.3 mph (0.5 km/h), the Controller will not regulate automatically.
1.1 Volume rate
0
gal/acre
Use arrow keys or numeric keys to set the desired volume rate.