PAGE 2.1 - 32 OPERATION MARK IV HD J2 TAMPER
REVISED 10 - 2020 CONTROLS BULLETIN 5082505
2.1
2.1.5 Control Panel - Center - See Figure 2.1-28
The Center Control Panel is located directly ahead of the operator’s seat. The Center Control
Panel houses the following controls:
(1) Jupiter Monitor
(2) Jupiter Keyboard
The Jupiter Monitor and Keyboard are located inside of a lockable enclosure with a removable
access cover. The monitor and keyboard are turned ON and OFF with the Jupiter On Switch
located in the Left Control Panel.
The touch screen monitor displays the operating screens in both the Travel and Work Modes.
The monitor displays the machine’s operating, set up and calibration functions, and diagnostic
screens for troubleshooting. See Operation - Jupiter II for a detailed description of the operating
screens.
The keyboard is a standard computer keyboard that can be used to enter or change the
machine’s operating, set up and/or calibration functions.
(3) Surfacing Indicator - Left
(4) Surfacing Indicator - Right
During surfacing operations when the shadowboard is positioned so the receiver photocells can
see the projector light beams, the applicable left and/or right red surfacing indicator will turn ON
to indicate that the Jacking Cycle will occur on that side only to lift the rail. If the shadowboard is
positioned so it has either or both of the projector light beams blocked, the applicable left or
right red surfacing indicator will turn OFF to indicate that the Jacking Cycle will NOT occur on
that side to lift the rail.
(5) Lining Indicator - Center
During lining operations when the shadowboard is positioned so the receiver photocell can see
the projector light beam, the center amber lining indicator will turn ON to indicate that the Lining
Cycle will move the track. If the shadowboard is positioned so it has the projector light beam
blocked, the center amber lining Indicator will turn OFF to indicate that the Lining Cycle is
completed.