570 MOD Functions
17.20 External Access
Example of TNC.SYS
Permitting/Restricting external access
U Select any machine mode of operation
U Press the MOD key to select the MOD function.
U Permit a connection to the TNC: Set the EXTERNAL
ACCESS soft key to ON. The TNC will then permit
data access through the LSV-2 interface. The
password is requested when a directory that was
entered in the configuration file TNC.SYS is accessed
U Block connections to the TNC: Set the EXTERNAL
ACCESS soft key to OFF. The TNC will then block
access through the LSV-2 interface
REMOTE.PERMISSION=PC2225;PC3547
REMOTE.TNCPASSWORD=KR1402
REMOTE.TNCPRIVATEPATH=TNC:\RK