6 System settings and service software
CargoPower installation and operation, revision - 01 53
6.1.6.1 General" tab
Motor calibration
Motor and control always form a fixed pairing. In order to match the motor and
controller to each other, each controller must be calibrated once to the respective motor
with which it is paired.
To do this, the procedure "Motor calibration" must be carried out.
In systems with several motors, this procedure must be carried out for each pairing of
motor and control unit.
A new motor calibration is always necessary if, for example, a motor
or a control unit is exchanged due to repair of a system, resulting in
a new pairing of motor and control unit.
Only a new motor calibration ensures the proper cooperation
between the motor and the control system!
Rotating parts
The motor rotates during calibration!
Danger of injuries due to rotating drive wheels
˃ Position the vehicle so that driven wheels can turn freely
˃ Never sit on the vehicle during calibration
The following conditions must be fulfilled so that the calibration
can be carried out correctly and is not falsified:
˃ Brake disks must not drag
˃ Prescribed tightening torques of the wheel nuts must be
observed
For further information, please refer to the technical information
"F_21_004_e_07_21_ED_CPS_ExperienceCalibration".
Select "Perform calibration".
The motor will now start to rotate!
Wait for the motor to stop