Operating Instructions • AT2000 CPK • 07-2019 • v03 • 106-29004
Troubleshooting
32
DISPLAY MESSAGE POSSIBLE CAUSE SOLUTION
1. Operate bandoleer cutter
2. Open gate
Error, drum
The cable tie bandoleer is
pulled in at an angle.
Roller lever drum is jammed
or is defective.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f Open the two transparent service flaps at the gate,
à"Troubleshooting a cable-tie bandoleer
malfunction" on page33.
; Error, drum appears as the next message on the
display.
1. Remove cable-tie residues
2. Press Reset button
Error, drum
f If applicable, carefully remove the cable-tie residues.
f Open the roller lever drum and turn the drum to the
correct position.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
f Load a new cable tie bandoleer, à"Loading cable
ties" on page11.
1. Operate bandoleer cutter
2. Open gate
Overload
The drum is blocked.
The bandoleer cutter does
not cut off the cable ties.
The cable tie bandoleer is
pulled in at an angle.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f Open the two service flaps at the gate,
à"Troubleshooting a cable-tie bandoleer
malfunction" on page33.
; Error, overload appears as the next message on
the display.
1. Remove cable-tie residues
2. Press Reset button
Overload
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
1. Operate bandoleer cutter
2. Open gate
Error, tensioning motor
Drive is jammed or is
defective.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
1. Check binding
2. Confirm with trigger
Error, binding force
The specified binding force
is not achieved.
The message appears only if
error notification is activated,
à"Check of binding" on
page16.
f Check the binding.
f If applicable, reset the binding force.
f If applicable, carefully remove the cable-tie residues.
f Press the trigger as confirmation.