Parking Detecon
Enable the funcon and set Judgment Time. If a vehicle has been parked for a duraon
longer than the set judgment me, the parking informaon will be upload.
3.
Set the relay funcon.
Note
The supported number of relays varies with dierent models. Relay 1 corresponds to the 1A and
1B of the terminal. Relay 2 corresponds to the 2A and 2B of the terminal.
4.
Select IO Funcon for the corresponding barrier gate related I/O. The device will upload barrier
gate status
informaon for convenient exit and entrance management.
Note
●
If the device only have one I/O interface, and the trigger type is I/O Coil, the barrier status
cannot be congured.
●
If the trigger type is Radar Mixed Trac and the forward radar and backward radar are
selected, the corresponding barrier gate related I/O
funcon cannot be congured. E.g., the
forward radar is IO1 and the backward radar is IO2. Then the barrier gate related IO1 and IO2
funcons cannot be congured.
5.
Set the barrier gate operaon and alarm operaon for the temporary vehicles, vehicles in the
blocklist, and vehicles in the allowlist in Vehicle Informaon Management.
Upload via SDK
Check Upload via SDK to arm and upload the vehicle
informaon to the arming terminal via
SDK.
Upload to Alarm Host
If the device has been connected to the alarm device, check Upload to Alarm Host. When the
barrier gate is open, the alarm device will be triggered to alarm.
6.
Oponal: You can click Close, Open, Unlock, or Lock to control the barrier gate remotely.
Note
The funcons of remote control of barrier gate vary with dierent models. The actual device
prevails.
7.
Click Save.
4.1.3 Set Wiegand Parameters
The device can get access to the access control system or other system
supporng Wiegand
protocols to send data in the entrance and exit scenes.
Steps
1.
Go to
Conguraon → Capture → Entrance and Exit → Wiegand Parameters .
2.
Check Enable.
Intelligent Entrance ANPR Camera User Manual