EasyManuals Logo

Hioki PW3198 User Manual

Hioki PW3198
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
13.7 Configuration Function Specifications
195
10
13
Chapter 13 Specifications
Quick setup pattern details
Abnormal voltage
detection
Basic power supply
quality measurement
Inrush current
measurement
Measured value
recording
EN50160
Connection Set in advance
Clamp sensor Set in advance
CT, PT ratios Set in advance
Measurement frequen-
cy
Automatic detection of 50/60/400 Hz; if unable to detect, user (manual) setting
Nominal input voltage Automatic detection; if unable to detect, user (manual) setting
Flicker/V10
(depends on selected
language)
Pst, Plt
(when Japanese is
selected, V10)
Pst, Plt
(when Japanese is
selected, V10)
Pst, Plt
(when Japanese is
selected, V10)
Pst, Plt
(when Japanese is
selected, V10)
Pst,Plt
Measurement RMS
voltage selection
Default Default Default Default Default
Measurement
harmonics selection
RMS value RMS value RMS value RMS value Content percentage
Total harmonic
distortion factor selection
THD_F THD_F THD_F THD_F THD_F
Power factor selection PF PF PF PF PF
Repeat setting and
iterations
OFF (max. 35 days) OFF (max. 35 days) OFF (max. 35 days) OFF (max. 35 days) OFF (max. 35 days)
Recorded items setting P&Harm (Normal) All Data (Full) P&Harm (Normal) All Data (Full) All Data (Full)
TIMEPLOT interval 1 minute 10 minutes 1 minute 10 minutes 10 minutes
Current range Automatic detection Automatic detection Max. range Automatic detection Automatic detection
Event hysteresis 1% 1% 1% 1% 2%
Transient overvoltage 70% of nominal
voltage
70% of nominal
voltage
OFF OFF 100% of nominal
voltage
Voltage swell 110% of nominal
voltage
110% of nominal
voltage
OFF OFF 110% of nominal
voltage
Voltage dip 90% of nominal
voltage
90% of nominal
voltage
OFF OFF 90% of nominal
voltage
Interruption 10% of nominal
voltage
10% of nominal
voltage
OFF OFF 1% of nominal
voltage
Frequency ±5 Hz of nominal
frequency
±0.5 Hz of nominal
frequency
OFF OFF ±0.5 Hz of nominal
frequency
Frequency cycle OFF OFF OFF OFF OFF
Voltage waveform
peak (±)
150% of reference
value
150% of reference
value
OFF OFF 170% of nominal
voltage
Voltage DC fluctuation
(±) (when DC is selected)
±10% based on DC
measured value
±10% based on DC
measured value
OFF OFF OFF
Current waveform
peak (±)
OFF 200% of reference
value
300% of reference
value
OFF OFF
Current DC fluctuation (±)
(when DC is selected)
±10% based on DC
measured value
±10% based on DC
measured value
OFF OFF OFF
RMS voltage 10% of reference
value
SENSE width: ±10 V
10% of reference
value
SENSE width: ±10 V
OFF OFF OFF
RMS current OFF
SENSE width: OFF
50% of reference
value
SENSE width: OFF
OFF
SENSE width: OFF
OFF
SENSE width: OFF
OFF
SENSE width: OFF
Inrush current
(Irms 1/2)
OFF OFF 200% of reference
value
OFF OFF
Active power OFF OFF OFF OFF OFF
Apparent power OFF OFF OFF OFF OFF
Reactive power OFF OFF OFF OFF OFF
Power factor/displace-
ment power factor
OFF OFF OFF OFF OFF
Setting
Pattern

Table of Contents

Other manuals for Hioki PW3198

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hioki PW3198 and is the answer not in the manual?

Hioki PW3198 Specifications

General IconGeneral
BrandHioki
ModelPW3198
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals