121
14. OPERATION RECORD LOGBOOK
Date Time
Motor 1st-Stage Air End 2nd-Stage Air End
2nd-Stage
Suction Air
Temperature
(℃ )
Ambient
Temperature
(℃ )
Oil
Temperature
(℃ )
Oil
Pressure
psi
(MPa)
Load
Ratio
%
Quantity of
Cooling
Water
gal
(ℓ)
Power
HP
(kW)
Total
Operation
Hours
h
Daily Control Remarks
Voltage
V
Current
A
Temperature
(℃ )
Pressure
psi
(MPa)
Temperature
(℃ )
Pressure
psi
(MPa)
Intercooler
Aftercooler
Condensate
Drain Trap
Oil Level
(Parts Change etc.)
Air-Cooled
Benchmarks
(Fixed speed type)
427 (219) or less When loading:
38 psi (0.26 MPa) or less When unloading:
-120 psi (-0.080 MPa)
436℉(224℃)or less
100 psi (0.69 MPa)or less
153
(67)
or less
104
(40)
or less
153
(67)
or less
19 to 26 psi
(0.13 to 0.18 MPa)
Condensate
drained
Condensate
drained
Condensate
drained
In oil level
gauge
490 (254) or less
125 psi (0.86 MPa) or less
Air-Cooled
Benchmarks
(V type)
436 (224)
When loading:
43 psi (0.29 MPa) or less 315 psi
(0.020.10 MPa) (Purging)
436℉(224℃)or less
100 psi (0.69 MPa)or less
13 to 26 psi
(0.09 to 0.18 MPa)
[7 to 23 psi
(0.05 to 0.16 MPa)]
Condensate
drained
Condensate
drained
In oil level
gauge
490 (254) or less
125 psi (0.86 MPa) or less
Water-Cooled
Benchmarks
(Fixed speed type)
409 (209) or less When loading:
38 psi(0.26 MPa) or less When
unloading:
-120 psi (-0.080 MPa)
418 (214℃)or less
100 psi (0.69 MPa)or less
148
(65)
or less
16 to 26 psi
(0.11 to 0.18MPa)
Condensate
drained
Condensate
drained
Condensate
drained
In oil level
gauge
472 (244℃)or less
125 psi (0.86 MPa)or less
Water-Cooled
Benchmarks
(V type)
409 (209)
When loading:
43 psi (0.29 MPa) or less 315
psi (0.020.10 MPa) (Purging)
418 (214℃)or less
100 psi (0.69 MPa)or less
13 to 26 psi
(0.09 to 0.18 MPa)
[7 to 23 psi
(0.05 to 0.16 MPa)]
Condensate
drained
Condensate
drained
In oil level
gauge
472 (244℃)or less
125 psi (0.86 MPa)or less
NOTES: 1. The marked items as well as the number of loading times are indicated on the LCD.
2. The values in the () are for the working pressure of 125psi (0.86 MPa).
3. Regarding mark, upper figure is for 45Hz driving frequency, lower figure in [ ] is for less than 45Hz driving frequency.