4. TROUBLESHOOTING
4.1 Protective Device
The air compressor is provided with the protective devices listed below. If shutdowns are detected by these protective
devices, remove the cause with referring to the LCD monitor indication and this manual, and then press the RESET
button to clear the shutdown indication. Depending on the type of shutdown, contact the local HITACHI distributor/
master dealer or representative office.
If a shutdown, alarm, problem or failure occurs, investigate the cause and take proper corrective action
before restarting. If there is any questions or comments, contact the local HITACHI distributor/master
dealer or representative office.
During Operation
The value in the [ ] is for water-cooled model
LCD Indication
What and How to Detect
Failure
Light
Detector
Shutdown
What Actions to Take
How to
Reset
History
code
Error
code
Heading Trouble Description
SHUTDOWN
1st stage discharge air temperature
(HIGH DIS. TEMP. 1)
About 437 [419]
225 [215]℃ or higher
SHUTDOWN
Blinks
Thermistor
Yes
4.2
Press RESET
button.
55 E0.55
1st stage discharge air temperature
The discharge temperature at 1st
stage rises above the below settings.
SHUTDOWN
Blinks
Thermistor
Yes
4.2
Press RESET
button.
55 E0.55
100 psi model
0.69 MPa model
about 446°F
[about 419°F]
about 230
[about 215]
125 psi model
0.86 MPa model
2nd stage discharge air
temperature
(HIGH DIS. TEMP. 2)
For working pressure of
100psi 0.69 MPa : About 446[428]
230 [220]℃ or higher
For working pressure of
125psi 0.86 MPa : About 500[482]
260 [250]℃ or higher
SHUTDOWN
Blinks
Thermistor
Yes
4.2
Press RESET
button.
56 E0.56
Interstage pressure
[Fixed speed type]
39psi 0.27MPa or higher
SHUTDOWN
Blinks
Pressure
sensor
Yes
4.2
Press RESET
button.
52 E0.52
Interstage pressure 44psi 0.30MPa or higher
SHUTDOWN
Blinks
Pressure
sensor
Yes
4.2
Press RESET
button.
52 E0.52
2nd stage suction air temperature
(2ND SUCT. TEMP)
163 [158]
73 [70]℃ or higher
SHUTDOWN
Blinks
Thermistor
Yes
4.2
Press RESET
button.
5B E0.5B
Oil temperature
(OIL HIGH TEMP)
163 [158]°F
73 [70]℃ or higher
SHUTDOWN
Blinks
Thermistor
Yes
4.2
Press RESET
button.
58 E0.58
Oil pressure
[Fixed speed type]
12 psi 0.08 MPa or lower
SHUTDOWN
Blinks
Pressure
sensor
Yes
4.2
Press RESET
button.
5C E0.5C
Oil pressure
(OIL-LOW PRESS)
For fi xed Speed type:
12 psi 0.08 MPaor lower
For Vtype:12psi 0.08 MPa or
lower (operating Freq. 45 Hz or
higher) 6psi
0.04MPa

or lower
(operating Freq. Less than 45 Hz)
SHUTDOWN
Blinks
Pressure
sensor
Yes
4.2
Press RESET
button.
5C E0.5C
Answer error of 52
239 115
or higher
(main motor bearing)
Blinks
in red
Thermo
stat
Yes
4.2
Press RESET
button.
51 E0.51
Overloading(main motor)
[Fixed speed type]
239 115
or higher
(main motor bearing)
Blinks
in red
Thermo
stat
Yes
4.2
Press RESET
button.
17 E0.17
Overloading (main motor) Detected during operation
SHUTDOWN
Blinks
Thermal
relay
Yes
4.2
Press RESET
button.
17 E0.17
Overloading (auxiliary motor)
Detected during operation
SHUTDOWN
Blinks
Thermal
relay
Yes
4.2
Press RESET
button.
53 E0.53
Answer error of 52
Detected during
running.
SHUTDOWN
Blinks
CPU Yes
4.2
Press RESET
button.
51 E0.51
Answer error of 42
[Fixed speed type]
Detected after shifting to
running.
SHUTDOWN
Blinks
CPU Yes
4.2
Press RESET
button.
16 E0.16
FAILURE
INV STOP
Inverter tripping or main
motor overloading with
automatic retrials.
Failure signal from inverter
SHUTDOWN
Blinks
CPU
Failure
stop after
repetition
of retrials.
4.2
Press RESET
button.
44 E0.44
CAUTION
When connecting the power
LCD Indication
What and How to Detect
Failure
Light
Detector
Shutdown
What Actions to Take
How to
Reset
History
code
Error
code
Heading Trouble Description
POWER
Reversal phase connection
(Note 2)
Detected for 3
seconds after
connecting the power
SHUTDOWN
Blinks
CPU
(Note 1)
Yes
Reconnect the power cable tightly, check the
power supply and incoming power for loose
connections and change the connection
location of 2 of the 3 phases, be sure to follow
all electrical safety procedures.
4.2.
Press RESET
button.
01 E0.01
Phase-lacking connection
CPU
(Note 1)
Yes
Reconnect the power cord tightly, check the
power supply, and take a corrective remedy.
02 E0.02
Instantaneous power interruption
Power interruption for 1 to 5 sec.
-
CPU
Restart
3.4.5
-
03 E0.03
Brief instantaneous power
interruption
Power interruption for
1 sec or less.
CPU
Restart
3.4.5 04 E0.04