3. OPERATING PROCEDURE [How to Use the Liquid Crystal Display (LCD)]
㻞㻜㻝㻞㻜㻥㻜㻝 㻝㻥䠖㻜㻞
㼀㼅㻼㻱㼂㻿㻰
㻌㻌 㻌㻌㻌
㻰㻵㻿㻿㻿 㼜㼟㼕
䠘㻾 㻿 㼀䠚
㻾㻱㻿㼀㻭㻾㼀 㻭㼀
㻾㻱㻿㼀㻭㻾㼀
㻺㻻㼃䠈㻿 㼀㻻㻼
㻿㻯㻴㻱㻰㼁㻸 㻿㼀㻻
㻭㼁㼀㻻 㻿㼀㻻㻼
㻰㻾㼅 㻼㻾㻱㻿㻭㻾㼀㻱㻰
㻰㼁㻭㻸㻮㻭㻯㻷㼁㻼
㻵㻼㻵 㻌㻾㻿
㻯㼀㻾䠊㻾㻱㻾㼅
Messages of Automatic Stop Display
When the air compressor stops automatically, the AUTO START light glows or blinks and RESTART display
appears. After the air compressor restarts, monitoring display appears again.
SCHEDULED STOP: Schedule operation setting
<AUTO light glows>
This indicates that the air compressor has been
automatically stopped by a pre-set time.
The air compressor starts automatically when the
pre-set restart time comes.
LEAD/LAG OPERATION STOP (option)
<AUTO light glows>
This indicates that the air compressor is waiting for
starting as a slave unit in a two-unit-alternate
operation or a backup operation.
DRYER PRESTARTED (Built-in dryer model)
<AUTO light blinks>
This indicates that the dryer has started and air
compressor is waiting for the start. The RESTART
WAIT field shows an expected waiting period until
the air compressor can start in seconds.
AUTO OPERATION
<AUTO light glows>
This indicates that the air compressor in AUTO
operation has stopped due to the low air demand and
is waiting for restarting when demand is needed.
The RESTART WAIT field shows an expected
waiting period until the air compressor can restart in
seconds.
INSTANT STOP / RETRY (Retry is for only Vtype)
<AUTO light blinks>
For both fixed speed and Vtype, this indicates that
the air compressor has stopped due to an
instantaneous power interruption (IPI). The
RESTART WAIT field shows an expected waiting
period until the air compressor can restart in
seconds.
For Vtype, this indicates that the air compressor has
stopped due to the variable speed drive failure and is
waiting for restart as well. The RESTART WAIT
field shows an expected waiting period until the air
compressor can restart in second.