CIPer
TM
MODEL 50 CONTROLLER INSTALLATION AND COMMISSIONING INSTRUCTIONS
31-00233-02
6
SAFETY INFORMATION
General Safety Information
When performing any work, all instructions given by the manufacturer and the safety instructions
provided in these Installation and Commissioning Instructions are to be observed. Make sure that the
local standards and regulations are always observed.
The CIPer Model 50 System (including the CIPer Model 50 controller, Panel Bus I/O modules, manual
disconnect modules, and auxiliary terminal packages) may be installed and mounted only by authorized
and trained personnel.
If the controller housing is damaged or missing, immediately disconnect it from any power.
If the device is broken or defective, do not attempt to repair it yourself; rather, return it to the
manufacturer.
It is recommended that devices be kept at room temperature for at least 24 hours before applying power.
This is to allow any condensation resulting from low shipping / storage temperatures to evaporate.
The CIPer Model 50 System must be installed in such a manner (e.g., in a lockable cabinet) as to ensure
that uncertified persons have no access to the terminals.
In the case of vertical mounting on DIN rails, the CIPer Model 50 controller should be secured in place
using a commercially available stopper.
If the CIPer Model 50 System is modified in any way, except by the manufacturer, all warranties
concerning operation and safety are invalidated.
Rules regarding electrostatic discharge should be followed.
Use only accessory equipment which comes from or has been approved by Honeywell.
Information as per EN 60730
Purpose
The purpose of the device is operating control. the CIPer Model 50 controller is a multifunctional non-safety
control device intended for HVAC in home (residential, commercial, and light-industrial) environments.
Construction
The CIPer Model 50 controller is an independently mounted electronic control unit with fixed wiring.
Mounting Method
The CIPer Model 50 controller is suitable for mounting as follows:
In cabinets;
In fuse boxes conforming with standard DINX3880, and having a slot height of max. 1.77” (45 mm);
In cabinet front doors (using accessory MVC-80-AC2);
On walls (using accessory MVC-80-AC1).
Table 1. Information as per EN 60730
Shock protection
Class II
Pollution degree
2
Installation
Class 3
Rated impulse voltage
330 V for SELV, 2500 V for relay outputs
Automatic action
Type 1.C (micro-interruption for the relay outputs)
Software class
Class A
Ball-pressure test temperature
Housing parts >167 °F (75°C)
Terminals >257 °F (125°C)