ANNEX
EnCal 3000
Hardware
Manual
73022344 o
122
Term
TermTerm
Term
Explanation
ExplanationExplanation
Explanation
Message is an event which applies to multiple evaluation cycles of the device. It
may be reset by a user with the appropriate user rights.
Network Time
Protocol.
NTP for the high-precision time synchronization of enCore devices
with an NTP time server.
Note is generated if a measurement violates a state defined by the user.
The start is entered in the error list with a time stamp and logged in
the logbook. Notes cannot be accepted and are automatically deleted
from the error list after the cause of the note has ended.
PELV PELV protective extra-low voltage systems which comply with
DIN EN 60079-14: the power supply to generate PELVs must ensure
that no short-circuit is possible between the primary voltage and the
extra-low voltage and its connections. It has a safe electrical isolation
point (safety isolation transformer) and complies with IEC 61558-2-6.
The circuits are earthed. All bodies of electrical equipment must be
connected to a common earthing (and equipotential bonding) sys
tem.
Place of use or installation site is the room or position at which the measuring
instrument is located. It must satisfy the defined requirements of the
manufacturers, authorities and operators.
Power-limited circuit
A power-limited circuit is a circuit separated from other circuits by at
least BASIC INSULATION in which the direct voltage (U) is no greater
than 60 V. The current which can occur in the circuit is limited by
certain measures to a value of less than 200/U. These measures must
interrupt the circuit within 120 seconds if this value is exceeded.
Process gas is the gas which is to be analyzed or measured. It is supplied to the
measuring equipment in normal operation and is also known as the
operating gas or sample gas.
SELV SELV safety extra-low voltage systems which comply with
DIN EN 60079-14: the power supply to generate SELVs must ensure
that no short-circuit is possible between the primary voltage and the
extra-low voltage and its connections. It has a safe electrical isolation
point (safety isolation transformer) and complies with IEC 61558-2-6.
Live parts of circuits must not be earthed or connected to live parts or
PE wires of other circuits. All bodies of electrical equipment cannot be
earthed (for example for electromagnetic compatibility).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ENCAL 3000 and is the answer not in the manual?

Honeywell ENCAL 3000 Specifications

General IconGeneral
BrandHoneywell
ModelENCAL 3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals