EasyManuals Logo

Honeywell NOTIFIER SLC User Manual

Honeywell NOTIFIER SLC
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6 Notifier SLC Wiring Manual — P/N 51253:U9 12/3/2021
Table of Contents
5.3.1: How an Isolator Base Works ................................................................................................................................................................31
5.4: NFPA Class B SLC Using Isolator Modules ...................................................................................................................................................33
5.5: NFPA Class A SLC Using Isolator Modules ...................................................................................................................................................35
5.6: NFPA Class X SLC Using an Isolating Device ...............................................................................................................................................36
Section 6: Monitor Modules............................................................................................................................................ 37
6.1: Description.......................................................................................................................................................................................................37
6.1.1: Addressable Monitor Module...............................................................................................................................................................37
6.1.2: Zone Interface Module .........................................................................................................................................................................37
6.1.3: Miniature Monitor Module...................................................................................................................................................................38
6.1.4: FMM-4-20 4-20mA Monitor Module ..................................................................................................................................................38
6.2: Setting an SLC Address for a Module .............................................................................................................................................................38
6.3: NFPA Class B IDC Using Monitor Modules...................................................................................................................................................39
6.4: NFPA Class A IDC Using Monitor Modules ...................................................................................................................................................40
6.5: NFPA Class B IDC Using Zone Interface Modules.........................................................................................................................................41
6.6: NFPA Class A IDC Using Zone Interface Modules.........................................................................................................................................42
Section 7: Control Modules ............................................................................................................................................ 44
7.1: Description.......................................................................................................................................................................................................44
7.1.1: Setting an SLC Address........................................................................................................................................................................44
7.2: Wiring a NAC with Addressable Control Modules .........................................................................................................................................44
7.2.1: Wiring a Solenoid with the FCM-1-REL .............................................................................................................................................45
7.3: Wiring a Class B NAC (Two-Wire) with Addressable Control Modules ........................................................................................................45
7.4: Wiring a Class A NAC (Four-Wire) with Addressable Control Modules........................................................................................................46
7.5: Connecting a Releasing Device to the Addressable Control Module..............................................................................................................47
Section 8: Relay Module ................................................................................................................................................. 49
8.1: Description.......................................................................................................................................................................................................49
8.1.1: Setting an SLC Address........................................................................................................................................................................49
8.2: Wiring the Addressable Relay Module (Form-C Relay) .................................................................................................................................49
Section 9: Multiple Input/Output Modules..................................................................................................................... 50
9.1: Description.......................................................................................................................................................................................................50
9.1.1: FDM-1 ..................................................................................................................................................................................................50
9.1.2: FDRM-1................................................................................................................................................................................................50
9.2: Setting the SLC Address..................................................................................................................................................................................50
9.2.1: FDM-1 ..................................................................................................................................................................................................50
9.2.2: FDRM-1................................................................................................................................................................................................50
9.3: Wiring the Dual Monitor Module ....................................................................................................................................................................50
9.4: Wiring the Addressable Dual Monitor/Dual Relay Module ............................................................................................................................51
9.5: NFPA Class B IDC Wiring Using Dual Monitor Modules ..............................................................................................................................51
Section 10: Intelligent Detectors, Intelligent Detector Bases, and Wireless Gateway.............................................. 53
10.1: Description.....................................................................................................................................................................................................53
10.1.1: Intelligent Detector Bases...................................................................................................................................................................53
10.1.2: Intelligent Aspiration Detectors..........................................................................................................................................................53
10.1.3: Wireless Gateway ...............................................................................................................................................................................54
10.2: Wiring a Detector Base ..................................................................................................................................................................................54
10.3: Wiring an Isolator Base .................................................................................................................................................................................56
10.4: Wiring a Relay Base ......................................................................................................................................................................................56
10.5: Wiring a Sounder Base ..................................................................................................................................................................................57
10.6: Wiring and Programming Aspiration Detectors ............................................................................................................................................58
10.7: Wiring the FWSG(A) ....................................................................................................................................................................................62
10.7.1: SLC Connections ................................................................................................................................................................................62
10.8: Power Connections: Powered by the SLC.....................................................................................................................................................63
10.8.1: Power Connections: External, Regulated +24 VDC Power Source ..................................................................................................64
Section 11: Addressable Manual Pull Stations............................................................................................................. 65
11.1: Description.....................................................................................................................................................................................................65
11.1.1: Setting an SLC address .......................................................................................................................................................................65
11.2: Wiring a Manual Pull Station.........................................................................................................................................................................65
Appendix A: Power Considerations .............................................................................................................................. 66
A.1: Supplying Power to 24 VDC Detectors and NACs ........................................................................................................................................66
A.2: Supervising 24 VDC Power............................................................................................................................................................................66

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell NOTIFIER SLC and is the answer not in the manual?

Honeywell NOTIFIER SLC Specifications

General IconGeneral
BrandHoneywell
ModelNOTIFIER SLC
CategoryControl Panel
LanguageEnglish

Related product manuals