38 SF61 Cordless Scanner User’s Guide
You scan a barcode, the SF61B beeps
twice, and the status light blinks green
twice, but the data is not transmitted
to the host computer.
Try these possible solutions:
Make sure that your data collection application is set up
to receive data from the SF61B.
If you are using an SD61 Base Station connected to your
host using an RS-232 cable, make sure that the serial
parameters on the SD61 match the serial parameters of
the host computer. The default serial parameters for the
SD61 are 19200 baud, 8 data bits, no parity, and 1 stop
bit.
You scan a configuration barcode and
the SF61B emits six very fast beeps.
The SF61B does not recognize or support the configuration
barcode you scanned.
You scan a barcode and the status
light turns on, but the SF61B does not
beep.
The beep duration, volume, frequency, and number may be
deactivated:
Use EasySet to check your product settings (see Online
Setup with EasySet on page 34) and reconfigure your
product if required.
You cannot establish a Bluetooth
connection with your scanner.
There may be a problem with your host Bluetooth interface, try
one or more of the following:
Disable then enable your host Bluetooth radio from the
Device Manager (Windows host) or equivalent for your
host device.
Disconnect then reconnect your Bluetooth adapter if
applicable.
Force a restart of your SF61B (hardware reset), see Force
a Hardware Reset in the present chapter).
Re-pair your scanner with your host device / application
(see the appropriate section in Chapter 2, Connect the
SF61B).
Your scanner may be connecting with / connected to
another Bluetooth host, disconnect the other Bluetooth
connection if required (see Chapter 2, Connect the
SF61B).
After a software reset:
By reading / sending a Reset
Factory Defaults command
By performing a firmware
upgrade
You can see the Outgoing and
Incoming virtual COM ports in your
host’s Bluetooth settings (SPP
connection) but your host device /
application tells you that they are not
available.
Depending on your host configuration (host device, Bluetooth
version), you may have to re-pair your product with your host
device /application to reset your scanner-host Bluetooth
settings (see the appropriate section in Chapter 2, Connect
the SF61B).
Problems and Possible Solutions (Continued)
Problem Possible Solution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SF61 Series and is the answer not in the manual?

Honeywell SF61 Series Specifications

General IconGeneral
BrandHoneywell
ModelSF61 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals