174 Voyager XP User Guide
This response indicates that Codabar Coding Enable (CBRENA) has a range of val-
ues from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
Enter: cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device’s current setting for Codabar Coding Enable?
Enter: cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example: What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First,
the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger
Mode barcode (page 78), or by sending a serial menu command for triggering
(page 79). Once the scanner is in serial trigger mode, the trigger is activated and
deactivated by sending the following commands:
Activate: SYN T CR
Deactivate: SYN U CR

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Voyager 1472g and is the answer not in the manual?

Honeywell Voyager 1472g Specifications

General IconGeneral
Environmental SealingIP42
Expected Duration of Operation14 hours
Expected Charge Time4.5 hours
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
IP RatingIP42
Weight210 g (7.4 oz)
ConnectivityBluetooth, USB
Scan PatternArea Image
Decode Capability1D
Battery2400 mAh Li-ion
Drop Specification1.5 m (5 ft) to concrete
Number of Scans50, 000 scans per charge
InterfaceUSB, RS232, Keyboard Wedge, IBM 46xx (RS485)
Humidity5% to 95% relative humidity, non-condensing
Dimensions173 mm x 62 mm x 82 mm (6.8 in x 2.4 in x 3.2 in)
Motion ToleranceUp to 70 cm/s (27.6 in/s) for 13 mil UPC
Scan TechnologyArea Imaging