Voyager XP User Guide 63
To see what the factory default settings are, refer to the table of Menu Commands,
beginning on page 175. The standard product default settings for each of the com-
mands are indicated by an asterisk (*).
Note: Scanning this barcode also causes both the scanner and the base or Access Point to
perform a reset and become unlinked. The scanner must be placed in the base, or the
Access Point linking barcode must be scanned to re-establish the link. Refer to
Scanner Modes for additional information.
If your scanner is in multiple scanner mode, you will hear up to 30 seconds of beeping
while all scanners are relinked to the base or Access Point and the settings are
changed.
Reset the Custom Defaults: All Application Work Groups
If you want the custom default settings restored to all of the work groups, scan the
Custom Product Default Settings barcode below. (If there are no custom defaults,
it will reset the work groups to the factory defaults.) See Set Custom Defaults on
page 1-8. for further information about custom defaults.
Note: Scanning this barcode also causes both the scanner and the base or Access Point to
perform a reset and become unlinked. The scanner must be placed in its base, or the
Access Point linking barcode must be scanned to re-establish the link. Refer to
Scanner Modes for additional information.
If your scanner is in multiple scanner mode, you will hear up to 30 seconds of beeping
while all scanners are relinked to the base or Access Point and the settings are
changed.
Use the Scanner with Bluetooth Devices
The scanner can be used either with the charge base, an Access Point, or with other
Bluetooth devices. Those devices include personal computers, laptops, PDAs, and
Honeywell mobility systems devices.
Bluetooth Secure Simple Pairing (SSP)
Secure Simple Pairing (SSP) allows you to connect simply and securely to other
Bluetooth devices without having to enter a PIN code (as described in Bluetooth
HID Keyboard Connect procedure). SSP is only available when using Bluetooth ver-
Custom Default Settings:
All Work Groups

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Voyager 1472g and is the answer not in the manual?

Honeywell Voyager 1472g Specifications

General IconGeneral
Environmental SealingIP42
Expected Duration of Operation14 hours
Expected Charge Time4.5 hours
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
IP RatingIP42
Weight210 g (7.4 oz)
ConnectivityBluetooth, USB
Scan PatternArea Image
Decode Capability1D
Battery2400 mAh Li-ion
Drop Specification1.5 m (5 ft) to concrete
Number of Scans50, 000 scans per charge
InterfaceUSB, RS232, Keyboard Wedge, IBM 46xx (RS485)
Humidity5% to 95% relative humidity, non-condensing
Dimensions173 mm x 62 mm x 82 mm (6.8 in x 2.4 in x 3.2 in)
Motion ToleranceUp to 70 cm/s (27.6 in/s) for 13 mil UPC