External Illumination Parameters
Absolute Maximum
Maximum voltage on out-
put pin with scanner pow-
ered down.
High Value: 6 Volts
This allows a pull-up to be
connected to this line provided
it does not exceed the current
on the next line of this table
while operating.
Maximum current driven
into pin from external
source.
High Value: 5mA
Maximum current limited by
series resistor dissipation.
Parameter Values
Output Low Voltage
Iout = 500uA
High Value: 0.6 Volts
Internal one-hundred ohm
series resistor drop included.
Output Low Voltage
Iout = 1mA
High Value: 0.7 Volts
Output Low Voltage
Iout = 4mA
High Value: 1.0 Volts
Output Low Voltage
Iout = 6mA
High Value: 1.2 Volts
Output High Voltage
Iout = -500uA
Low Value: 3.6 Volts
Output High Voltage
Iout = -1mA
Low Value: 3.5 Volts
Output High Voltage
Iout = -4mA
Low Value: 3.3 Volts
Output High Voltage
Iout = -6mA
Low Value: 3.1 Volts