2 - 26
Scanner-Bioptic Packet Mode
Packet Mode On must be scanned to set the scanner’s format so it is com-
patible with a bioptic scanner. Default = Packet Mode Off.
Scanner-Bioptic ACK/NAK Mode
Bioptic ACK/NAK On must be scanned so the scanner will wait for an
ACK or NAK from a bioptic scanner after each packet is sent. The Scan-
ner-Bioptic ACK/NAK Timeout (below) controls how long the scanner will
wait for a response. Default = Bioptic ACK/NAK Off.
Scanner-Bioptic ACK/NAK Timeout
This allows you to set the length (in milliseconds) for a timeout for a bioptic
scanner’s ACK/NAK response. Scan the bar code below, then set the tim-
eout (from 1-30,000 milliseconds) by scanning digits from the inside back
cover, then scanning Save. Default = 5100.
* Packet Mode Off
Packet Mode On
* Bioptic ACK/NAK Off
Bioptic ACK/NAK On
ACK/NAK Timeout