2 - 5
Verifone
®
Ruby Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Veri-
fone Ruby terminal. This bar code sets the baud rate to 1200 bps and the
data format to 8 data bits, Mark parity bit, 1 stop bit. It also adds a line feed
(LF) suffix an programs the following prefixes for each symbology:
Note: If you are having unexpected results with this programming code,
scan the Activate Defaults bar code on page 1-5 first, then scan the
programming code above.
Gilbarco
®
Terminal Default Settings
Scan the following Plug and Play code to program the scanner for a Gil-
barco terminal. This bar code sets the baud rate to 2400 bps and the data
format to 7 data bits, even parity, 2 stop bits. It also adds a carriage return
(CR) suffix and programs the following prefixes for each symbology:
Note: If you are having unexpected results with this programming code,
scan the Activate Defaults bar code on page 1-5 first, then scan the
programming code above.
Symbology Prefix
UPC-A A
UPC-E A
EAN-8 FF
EAN-13 F
Symbology Prefix
UPC-A A
UPC-E E0
EAN-8 FF
EAN-13 F