4 - 3
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2. Determine the 2 digit Hex value from the Symbology Chart
(included in the Symbology Charts beginning on page A-1) for the
symbology from which you want to clear the prefix or suffix.
Step 3. Scan the 2 digit hex value from the Programming Chart inside the
back cover of this manual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to
All Symbologies
Scan the following bar code if you wish to add a carriage return suffix to all
symbologies at once. This action first clears all current suffixes, then pro-
grams a carriage return suffix for all symbologies.
Prefix Selections
Add CR Suffix
All Symbologies
Add Prefix
Clear One Prefix
Clear All Prefixes

Table of Contents

Other manuals for Honeywell Vuquest 3310g

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Vuquest 3310g and is the answer not in the manual?

Honeywell Vuquest 3310g Specifications

General IconGeneral
TypeFixed bar code reader
Sensor type-
Yaw reading angle-65 - 65 °
Pitch reading angle-45 - 45 °
Optical sensor resolution838 pixels
Light levels (direct sunlight)0 - 100000 lx
Standard interfacesPS/2
Connectivity technologyWired
Input voltage5 V
Power consumption450 mA
Power source typeAC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
Product colorWhite
International Protection (IP) codeIP53
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedUSB
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width50 mm
Height26 mm
Weight75 g