EasyManuals Logo

Honeywell Vuquest 3310g User Manual

Honeywell Vuquest 3310g
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
4 - 6
To remove this delay, scan the Intercharacter Delay bar code, then set the
number of delays to 0. Scan the Save bar code using the Programming
Chart inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may
be placed after the transmission of a particular character of scanned data.
Scan the Delay Length bar code below, then scan the number of 5ms
delays, and the Save bar code using the Programming Chart inside the
back cover of this manual.
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex
value for the ASCII character that will trigger the delay ASCII Conversion
Chart (Code Page 1252), beginning on page A-4.
To remove this delay, scan the Delay Length bar code, and set the number
of delays to 0. Scan the Save bar code using the Programming Chart
inside the back cover of this manual.
Interfunction Delay
An interfunction delay of up to 5000 milliseconds (in 5ms increments) may
be placed between the transmission of each control character in the mes-
sage string. Scan the Interfunction Delay bar code below, then scan the
number of 5ms delays, and the Save bar code using the Programming
Chart inside the back cover of this manual.
Delay Length
Character to Trigger Delay
Interfunction Delays
Prefix Scanned Data Suffix
1 2345STX HT CR LF
Interfunction Delay

Table of Contents

Other manuals for Honeywell Vuquest 3310g

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Vuquest 3310g and is the answer not in the manual?

Honeywell Vuquest 3310g Specifications

General IconGeneral
TypeFixed bar code reader
Sensor type-
Yaw reading angle-65 - 65 °
Pitch reading angle-45 - 45 °
Optical sensor resolution838 pixels
Light levels (direct sunlight)0 - 100000 lx
Standard interfacesPS/2
Connectivity technologyWired
Input voltage5 V
Power consumption450 mA
Power source typeAC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
Product colorWhite
International Protection (IP) codeIP53
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedUSB
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width50 mm
Height26 mm
Weight75 g