3 - 7
mand is sent. The scanner can also be set to turn itself off after a specified time
has elapsed (see Read Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s button
when using serial commands to trigger the scanner. Once the scanner has
timed out, you can activate the scanner either by pressing the button or
using a serial trigger command. After scanning the Read Time-Out bar
code, set the time-out duration (from 0-300,000 milliseconds) by scanning
digits on the Programming Chart inside the back cover, then scanning
Save. Default = 30,000 ms.
Presentation Mode
Presentation Mode uses ambient light and scanner illumination to detect bar
codes. When in Presentation Mode, the LEDs remain dim until a bar code is
presented to the scanner, then the aimer turns on and the LEDs turn up to read
the code. If the light level in the room is not high enough, Presentation Mode
may not work properly
Scan the following bar code to program your scanner for Presentation Mode.
Read Time-Out
Presentation Mode