Page #77 background imageLoading...
Page #77 background image
3 - 27
When the output sequence is Off, the bar code data is output to the host as
the scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple
symbols with a single press of the scanners button. If you press and hold the
button, aiming the scanner at a series of symbols, it reads unique symbols
once, beeping (if turned on) for each read. The scanner attempts to find and
decode new symbols as long as the button is pressed. When this programming
selection is turned Off, the scanner will only read the symbol closest to the aim-
ing beam. Default = Off.
Required
On/Not Required
*Off
On
* Off

Table of Contents

Other manuals for Honeywell Vuquest 3310g

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Vuquest 3310g and is the answer not in the manual?

Honeywell Vuquest 3310g Specifications

General IconGeneral
TypeFixed bar code reader
Sensor type-
Yaw reading angle-65 - 65 °
Pitch reading angle-45 - 45 °
Optical sensor resolution838 pixels
Light levels (direct sunlight)0 - 100000 lx
Standard interfacesPS/2
Connectivity technologyWired
Input voltage5 V
Power consumption450 mA
Power source typeAC
Power consumption (standby)0.45 W
Power consumption (typical)2.3 W
Product colorWhite
International Protection (IP) codeIP53
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Cables includedUSB
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width50 mm
Height26 mm
Weight75 g