Clearing a Password
There is a Password Clear button on the HP Ethernet SNMP Module that
is accessed through a hole in the hub’s Expansion Slot cover plate. You
can use this button to clear a forgotten password that was previously
configured on the hub. The password is configured from either:
HP Stack Manager
HP Interconnect Manager, or
ASCII terminal interface
To clear the password, press and hold the button for approximately
five seconds.
As an indication that the password has been cleared, the Security LED
on the front of the hub will come on and stay on until the button is
released.
Note After the password has been cleared, access to the hub from the
HP Stack Manager and from SNMP management stations will no longer
be password protected.
Press the Password Clear
button with a pen or other
pointed object.
Troubleshooting