ZPWY-MAP- Definitions
NonStop Pathway/iTS Management Programming Manual—426749-002
6-69
ZPWY-MAP-STATS-TERM2
ZMEASCOUNTACTIVE
is the number of time intervals. If no frequency distribution table is
generated because ZTOTALMEASCOUNT is less than 50 or ZTIMEINCR
is less than 0.01 second, the value of ZMEASCOUNTACTIVE is 0. For
Pathway C31, ZMEASCOUNTACTIVE is fixed at 20.
ZMINTIME
is the value of the first time interval.
ZTIMEINCR
is the time increment from one interval to the next.
For additional information on the frequency distribution table, see the
Pathway/iTS System Management Manual.