TCP Event Messages
NonStop Pathway/iTS Management Programming Manual426749-002
11-127
3073: ZPWY-EVT-TCP-INSUFFTERMPOOL
A SCREEN COBOL statement required a larger terminal input buffer than was
configured.
For a description of tokens that are present in this event message but are not listed or
described here, see the TS/MP Management Programming Manual.
Token Descriptions
ZEMS-TKN-EMPHASIS
has the value ZSPI-VAL-FALSE.
ZEMS-TKN-EVENTNUMBER
contains ZPWY-EVT-TCP-INSUFFTERMPOOL (3073).
ZEMS-TKN-SUBJECT-MARK
indicates ZPWY-TKN-TCPNAME, which contains the name of the TCP process
that is the subject of this event message.
ZPWY-TKN-EVENTCLASS
has the value ZPWY-VAL-ERROREVENT.
ZPWY-TKN-BUFFERLENGTH
contains the buffer size, in bytes, that was required by a SCREEN COBOL
statement but could not be provided.
Unconditional Tokens
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT.
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-SSCTL.
ZPWY-TKN-TCPNAME token-type ZPWY-TYP-TCPNAME.
ZPWY-TKN-EVENTCLASS token-type ZSPI-TYP-ENUM.
Conditional Tokens
ZPWY-TKN-BUFFERLENGTH token-type ZPSI-TYP-INT2.
ZPWY-TKN-INSTRUCTION token-type ZSPI-TYP-ENUM.
ZPWY-TKN-PUNAME token-type ZSPI-TDT-STRUCT.
ZPWY-TKN-PUOFFSET token-type ZSPI-TYP-INT2.
ZPWY-TKN-PUVERSION token-type ZSPI-TYP-INT2.
ZPWY-TKN-TCLPROGFNAME token-type ZSPI-TYP-FNAME32.
Event-Message Text
*3073* INSUFFICIENT TERMPOOL FOR REQUEST ( < bytes > )

Table of Contents