ZPWY-DDL- Definitions
NonStop Pathway/iTS Management Programming Manual426749-002
5-20
ZPWY-DDL-TMF-RESTARTS
If a value for ZSUBTYPE is not specified in the TERMINAL IS clause of a
program for an intelligent device or in ZPWY-DDL-TERMTYPE-INFO, a default
value is used rather than the value obtained from the file-system DEVICEINFO
call.
ZPWY-DDL-TMF-RESTARTS
ZPWY-DDL-TMF-RESTARTS specifies the maximum number of times a TCP can
attempt to restart a logical TMF transaction after the transaction aborts and before the
SEND error occurs.
The following values are valid:
ZPWY-DDL-YES-NO
ZPWY-DDL-YES-NO specifies a yes or no decision. Valid values are ZPWY-VAL-YES
or ZPWY-VAL-NO.
ZPWY-DDL-0-2045
ZPWY-DDL-0-2045 is a value from 0 through 2045.
ZPWY-DDL-0-2250
ZPWY-DDL-0-2250 is a value from 0 through to 2250.
def ZPWY-DDL-TMF-RESTARTS token-type ZSPI-DDL-INT2.
0 No restarts
-1 Unlimited number of restarts
1 through 32,767 Number of restarts specified
def ZPWY-DDL-YES-NO token-type ZSPI-DDL-BOOLEAN.
Note. ZPWY-VAL-YES is equivalent to ZSPI-VAL-TRUE, and ZPWY-VAL-NO is equivalent to
ZSPI-VAL-FALSE, neither of which is supported in COBOL. For information on working with
Boolean values and COBOL coding suggestions, see the SPI Programming Manual.
def ZPWY-DDL-0-2045 token-type ZSPI-DDL-INT.
def ZPWY-DDL-0-2250 token-type ZSPI-DDL-INT.