TCP Event Messages
NonStop Pathway/iTS Management Programming Manual426749-002
11-250
3209: ZPWY-EVT-TCP-NOMICRO
The microcode required to operate the Pathway subsystem is not installed.
For a description of tokens that are present in this event message but are not listed or
described here, see the TS/MP Management Programming Manual.
Token Descriptions
ZEMS-TKN-EMPHASIS
has a value of ZSPI-VAL-FALSE.
ZEMS-TKN-EVENTNUMBER
contains ZPWY-EVT-TCP-NOMICRO (3209).
ZEMS-TKN-SUBJECT-MARK
indicates ZPWY-TKN-TCPNAME, which contains the name of the TCP that is the
subject of this event message.
ZPWY-TKN-EVENTCLASS
has a value of ZPWY-VAL-ERROREVENT.
Effect. The TCP terminates.
Recovery. Install Pathway microcode before starting the Pathway subsystem.
Unconditional Tokens
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT.
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-SSCTL.
ZPWY-TKN-TCPNAME token-type ZPWY-TYP-TCPNAME.
ZPWY-TKN-EVENTCLASS token-type ZSPI-TYP-ENUM.
Event-Message Text
*3209* TCP tcp-name, PROCESSOR DOES NOT HAVE PATHWAY
MICROCODE