TCP Event Messages
NonStop Pathway/iTS Management Programming Manual426749-002
11-125
3072: ZPWY-EVT-TCP-ILLRUNTIMEATTRS
During the run-time processing of a control structure associated with a CONTROLLED
clause, an invalid token name or an invalid value has been detected, or the specified
token count has caused an out-of-bounds condition to occur.
For a description of tokens that are present in this event message but are not listed or
described here, see the TS/MP Management Programming Manual.
Token Descriptions
ZEMS-TKN-EMPHASIS
has the value ZSPI-VAL-FALSE.
ZEMS-TKN-EVENTNUMBER
contains ZPWY-EVT-TCP-ILLRUNTIMEATTRS (3072).
ZEMS-TKN-SUBJECT-MARK
indicates ZPWY-TKN-TERMNAME, which contains the name of the terminal that is
the subject of this event message.
ZPWY-TKN-EVENTCLASS
has the value ZPWY-VAL-ERROREVENT.
ZPWY-TKN-INSTRUCTION
contains the instruction executing at the time the error was detected.
Unconditional Tokens
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT.
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-SSCTL.
ZPWY-TKN-TERMNAME token-type ZPWY-TYP-TERMNAME.
ZPWY-TKN-EVENTCLASS token-type ZSPI-TYP-ENUM.
Conditional Tokens
ZPWY-TKN-INSTRUCTION token-type ZSPI-TYP-ENUM.
ZPWY-TKN-PUNAME token-type ZSPI-TDT-STRUCT.
ZPWY-TKN-PUOFFSET token-type ZSPI-TYP-INT2.
ZPWY-TKN-PUVERSION token-type ZSPI-TYP-INT2.
ZPWY-TKN-TCLPROGFNAME token-type ZSPI-TYP-FNAME32.
Event-Message Text
*3072* RUN-TIME ATTRIBUTE SETTING INVALID

Table of Contents