IP Routing Features
Configuring DHCP Relay
Minimum Requirements for DHCP Relay Operation
In order for the DHCP Relay agent to work, the following steps must be
completed:
1. DHCP Relay is enabled on the routing switch
2. A DHCP server is servicing the routing switch
3. IP Routing is enabled on the routing switch
4. There is a route from the DHCP server to the routing switch and back
5. An IP Helper address is configured on the routing switch, set to the IP
address of the DHCP server on the VLAN that is connected to the DHCP
Client.
Enabling DHCP Relay
To enable the DHCP Relay function for the routing switch, at the Config CLI
context level, enter the command:
ProCurve(config)# dhcp-relay
To disable the DHCP Relay function, enter the command:
ProCurve(config)# no dhcp-relay
Configuring a Helper Address
At the VLAN configuration CLI context level, enter the commands to add the
DHCP server’s IP address to the VLANs list. For example, to configure a helper
address of 18.38.127.53 for VLAN 1, you would enter these commands:
ProCurve(conf)# vlan 1
ProCurve(vlan-1)# ip helper-address 18.38.127.53
To remove the DHCP server helper address 18.38.127.53 , you would enter this
command:
ProCurve(vlan-1)# no ip helper-address 18.38.127.53
7-27

Table of Contents

Other manuals for HP ProCurve 2610

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2610 and is the answer not in the manual?

HP ProCurve 2610 Specifications

General IconGeneral
Switching Capacity12.8 Gbps
Forwarding Rate9.5 Mpps
MAC Address Table Size8000 entries
LayerLayer 2
RAM64 MB
Flash Memory16 MB
Jumbo Frame SupportYes
ManageableYes
Operating Humidity15% to 95% non-condensing
Ports24 x 10/100
VLANs256
ManagementWeb, CLI, SNMP
Power SupplyInternal
Operating Temperature0°C to 40°C
Dimensions (W x D x H)17.42 x 12.73 x 1.73 in

Related product manuals