32 HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide
If the fan zone is not operating with redundancy, power down the server
("Powering Down the Server" on page 20).
If the fan zone is operating with redundancy, continue with the next step.
4. Remove the fan.
CAUTION: Do not operate the server for long periods without
the access panel. Operating the server without the access panel results
in improper airflow and improper cooling that can lead to thermal
damage.
IMPORTANT: For optimum cooling, install fans in all primary fan
locations. For more information, refer to the previous fan locations table.
To replace the component, reverse the removal procedure.
PCI Riser Cage Door Latch
To remove the component:
1. Extend or remove the server from the rack ("Extending the Server from the
Rack" on page 18, "Removing the Server from the Rack" on page 21).
2. Remove the access panel ("Removing the Access Panel" on page 21).