Hardware options installation 135
Server #1 + FSBBU
module load
condition (%)
Server #2 + FSBBU
module load
condition (%)
Supported (Yes/No)
where server #1 lost
input AC power
Supported (Yes/No)
where server #2 lost
input AC power
10 (75W- 6.25A)
90 (675W- 56.25A)
Yes
No
20 (150W- 12.5A)
80 (600W- 50A)
Yes
No
30 (225W- 18.5A)
70 (525W- 43.5A)
Yes
No
40 (300W- 25A)
60 (450W- 37.5)
Yes
Yes
50 (375W- 31.25)
50 (375W- 31.25)
Yes
Yes
60 (450W- 37.5)
40 (300W- 25A)
Yes
Yes
70 (525W- 43.5A)
30 (225W- 18.5A)
No
Yes
80 ( 600W- 50A)
20 (150W- 12.5A)
No
Yes
90 (675W- 56.25A)
10 (75W- 6.25A)
No
Yes
Installing the FSBBU
CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis
unless all bays are populated with a component or a blank.
To install the component:
1. Access the product rear panel (on page 28).
2. Remove the blank.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the FSBBU or
power supply blank to cool before touching it.
3. Press the battery check button located on the rear of the FSBBU module to check the battery
condition before installing the unit into the power supply bay. To locate the battery check button and
for more information on the FSBBU module LED status, see "Flex slot battery backup module LEDs
and buttons (on page 15)."