Specifications 197
HPE 1400W Flex Slot Platinum Plus Hot-plug Power Supply
Input requirements
Rated input voltage
240 VDC for China only
Rated input frequency
Not applicable to 240 VDC
Rated input current
6.7 A at 240 VAC
6.7 A at 240 VDC for China only
Maximum rated input power
1600 W at 240 VAC
1600 W at 240 VDC for China
only
BTUs per hour
5459 at 240 VAC
5459 at 240 VDC for China only
Power supply output
Rated steady-state power
1400 W at 200 VAC to 240 VAC
input
1400 W at 240 VDC input for
China only
Maximum peak power
1400 W at 200 VAC to 240 VAC
input
1400 W at 240 VDC input for
China only
HPE 750W Flex Slot Hot-plug Battery Backup
Module
Maximum discharge current
Maximum runtime
– Full load, 750 W
– 75% load, 564 W
– 50% load, 375 W
>60 seconds
145 seconds
220 seconds
300 seconds (limited by user)
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, see the Hewlett Packard Enterprise Power Advisor website
(http://www.hpe.com/info/poweradvisor/online).