Component identification 24
NVMe SSD components
The NVMe SSD is a PCIe bus device. A device attached to a PCIe bus cannot be removed without
allowing the device and bus to complete and cease the signal/traffic flow.
CAUTION: Do not remove an NVMe SSD from the drive bay while the Do Not Remove
button LED is flashing. The Do Not Remove button LED flashes to indicate the device is still in
use. Removal of the NVMe SSD before the device has completed and ceased signal/traffic
flow can cause loss of data.
Item
Description
1
Release lever
2
Activity ring
3
Do Not Remove button
4
Power button
Hot-plug fans
CAUTION:
To avoid damage to server components, fan blanks must be installed in fan bays
1 and 2 in a single-processor configuration.
CAUTION: To avoid damage to the equipment, do not operate the server for extended
periods of time if the server does not have the optimal number of fans installed. Although the
server might boot, Hewlett Packard Enterprise does not recommend operating the server
without the required fans installed and operating.
Valid fan configurations are listed in the following table.
Configuration
Fan bay 1
Fan bay 2
Fan bay 3
Fan bay 4
Fan bay 5
Fan bay 6
1 processor
Fan blank
Fan blank
Fan
Fan
Fan
Fan
1 processor, 24 SFF or
12 LFF configuration
with high-performance
fans
Fan
Fan
Fan
Fan
Fan
Fan
2 processors
Fan
Fan
Fan
Fan
Fan
Fan