Procedure
1. Navigate to the Maintenance > Library Tests > Position Test screen.
2. Select the source and destination element addresses and number of cycles.
3. Click Start.
Performing the wellness test
The wellness test exercises basic library functionality. At the end of the test, cartridges will be in different
storage slots.
CAUTION:
The test can move cartridges between partitions. Especially if the library is configured for
encryption, ensure that all cartridges are returned to their original partitions after the test.
Prerequisites
• At least one drive must be empty.
• At least one cartridge that is compatible with the empty drive must be in a magazine slot or mailslot.
If moving a cartridge to or from a tape drive, the cartridge must be compatible with the generation of
the tape drive.
• One of the selected element locations must be empty and one of the selected element locations must
be full.
• Each library module must have at least one cartridge installed.
• All backup operations are stopped.
The test takes the library offline to hosts for the duration of the test.
Procedure
1. Navigate to the Maintenance > Library Tests > Wellness Test screen.
2. Click Start Test.
Performing the robotic test
The robotic test performs a full inventory and exercises all robotic assembly movements and sensors.
Procedure
1. Navigate to the Maintenance > Library Tests > Robotic Test screen.
2. Click Start Test.