35
No display on the configuration terminal
Symptom
The configuration terminal has no display when the switch is powered on.
Solution
To resolve the issue:
1. Verify that the power system is operating correctly.
2. Verify that the console cable has been connected correctly and no fault occurs on the console
cable.
3. Verify that the following settings are configured for the terminal:
{ Baud rate—9600.
{ Data bits—8.
{ Stop bits—1.
{ Parity—None.
{ Flow control—None.
4. If the issue persists, contact Hewlett Packard Enterprise Support.
Garbled display on the configuration terminal
Symptom
The configuration terminal displays garbled text.
Solution
To resolve the issue:
1. Verify that the following settings are configured for the terminal:
{ Baud rate—9600.
{ Data bits—8.
{ Stop bits—1.
{ Parity—None.
{ Flow control—None.
2. If the issue persists, contact Hewlett Packard Enterprise Support.

Table of Contents

Other manuals for HPE FlexFabric 5710 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5710 Series and is the answer not in the manual?

HPE FlexFabric 5710 Series Specifications

General IconGeneral
ModelHPE FlexFabric 5710 Series
Power SupplyAC or DC
Operating Temperature0°C to 45°C
Routing ProtocolOSPF, BGP, RIP
Input Voltage100-240V AC
Operating Humidity10% to 90% (non-condensing)
Jumbo Frame SupportUp to 9216 bytes
ManagementCLI, SNMP

Related product manuals