Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
ProcedureProcedure
1. Back up all server data.
2. If installed, remove the front bezel .
3. Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
7. Remove the access panel.
8. Remove the universal media bay blank.
Enable the enhanced cooling functionEnable the enhanced cooling function
About this taskAbout this task
The server generates more heat when Intel Xeon Gold 6244 Processor is installed. To maintain proper cooling, increase the fan speed.
ProcedureProcedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Fan and
Thermal Options > Thermal Configuration.